China Elastomeric Insulation For Ultra Low Temperature Pipeline Manufacturers, Factories

When the operating temperature of the pipeline is lower than -180℃,consideration should be given to laying the vapor layer on the ULT of the ultra-low temperature adiabatic system to prevent liquid oxygen from forming on the metal pipe wall.

Product Description

Insulation Application
Insulation Material Details
Insulation Installation

The flexible ULT insulation system does not need to install a moisture barrier. Due to the unique closed cell structure and polymer blend formulation, the LT low temperature elastomeric material is highly resistant to water vapor permeation.

Performance Graph
Product Structure
Technical Specifications
Property Base material Test Method
ULT LT
Thermal Conductivity -100°C, 0.028
-165°C, 0.021
0°C, 0.033
-50°C, 0.028
ASTM C177
Density Range 60-80Kg/m³ 40-60Kg/m³ ASTM D1622
Recommend Operation Temperature -200°C to 125°C -50°C to 105°C -
Percentage Of Close Areas >95% >95% ASTM D2856
Moisture Performance Factor NA <1.96x10⁻¹¹g/(m·s·Pa) ASTM E 96
Wet resistance Factor NA >10000 EN12086
EN13469
Water Vapor Permeability Coefficient NA 0.0039g/h.m²
(25mm thickness)
ASTM E 96
PH ≥8.0 ≥8.0 ASTM C871
Tensile Strength MPa -100°C, 0.30
-165°C, 0.25
0°C, 0.15
-50°C, 0.218
ASTM D1623
Compressive Strength MPa -100°C, ≤0.3 -40°C, ≤0.16 ASTM D1621
  • Maintains flexibility down to -200℃ to 125℃
  • Protects against corrosion under insulation
  • Low thermal conductivity
  • Easy installation for complex shapes
Dimension Details
Inches mm Size (L*W) ㎡/Roll
3/4" 20 10 × 1 10
1" 25 8 × 1 8
Production Process
Testing Phase
Quality Control
Finished Insulation Roll
Packaging Detail
Warehouse Storage

Frequently Asked Questions

Q1: Does the ULT insulation system require an additional moisture barrier?
No, the ULT insulation system does not require the installation of an external moisture barrier. Its unique closed-cell structure provides built-in, high-level resistance to water vapor permeation.
Q2: What is the recommended operation temperature range for the insulation materials?
The ULT material operates within a temperature range of -200°C to 125°C, maintaining flexibility even at extreme cryogenic temperatures. The LT variant is recommended for temperatures between -50°C and 105°C.
Q3: How does the material prevent corrosion under insulation (CUI)?
By featuring a high closed-cell percentage (greater than 95%) and a neutral-to-alkaline pH level (≥8.0), the system mitigates moisture buildup and corrosive chemical environments, preventing the risk of CUI.
Q4: What are the primary thermal conductivity values of the ULT and LT materials?
According to ASTM C177 testing, the ULT material achieves a thermal conductivity of 0.021 W/(m·K) at -165°C, while the LT material exhibits a conductivity of 0.033 W/(m·K) at 0°C.
Q5: Can the insulation be easily installed on complex piping and shapes?
Yes. Because the elastomeric material retains its flexibility down to low temperatures, it conforms easily to complex geometries, elbows, and valves, allowing for a straightforward and secure installation.