1 / 2
| Technical Data Specification | |||
|---|---|---|---|
| Property | Unit | Value | Test Method |
| Temperature range | °C | -50 to 110 | GB/T 17794-1999 |
| Density range | Kg/m³ | 45-65 | ASTM D1667 |
| Water vapor permeability | Kg/(m.s.pa) | ≤0.91×10⁻¹³ | DIN 52 615 / BS 4370 Part 2 1973 |
| μ (Water vapor diffusion resistance) | - | ≥10000 | - |
| Thermal Conductivity | W/(m.k) | ≤0.030 (-20°C) | ASTM C 518 |
| ≤0.032 (0°C) | |||
| ≤0.036 (40°C) | |||
| Fire Rating | - | Class 0 & Class 1 | BS 476 Part 6 & Part 7 |
| Flame Spread and Smoke Developed Index | - | 25/50 | ASTM E 84 |
| Oxygen Index | - | ≥36 | GB/T 2406, ISO 4589 |
| Water Absorption, % by Volume | % | 20% | ASTM C 209 |
| Dimension Stability | - | ≤5 | ASTM C534 |
| Fungi resistance | - | Good | ASTM G21 |
| Ozone resistance | - | Good | GB/T 7762-1987 |
| Resistance to U.V. and weather | - | Good | ASTM G23 |