Wholesale Elastomeric Rubber Foam Insulation For Ultra Low Temperature System Factory, Quotes

Kingflex ULT Kingflex ULT is a flexible, high density and mechanically roubust, closed cell cryogenic thermal insulation material based on extrude elastomeric foam.

Product Description

Insulation Component 1
Insulation Component 2
Insulation Component 3
Insulation Material Application
Structure Performance
Insulation Sheet
Material Design
Production Process
Finished Insulation

Kingflex flexible ultra low temperature adiabatic system has the inherent characteristics of impact resistance, and its cryogenic elastomer material can absorb the impact and vibration energy caused by the external machine to protect the system structure.

Dimension Diagram
Dimension Specifications
Inches mm Size (L * W) ㎡ / Roll
3/4" 20 10 × 1 10
1" 25 8 × 1 8

Kingflex ULT insulation can be used in Low temperature storage tank; industrial gas and agricultural chemical production plants; platform pipe; gas station; nitrogen plant...

Property Comparison Overview
Property Base material Standard / Test Method
Kingflex ULT Kingflex LT
Thermal Conductivity -100°C, 0.028
-165°C, 0.021
0°C, 0.033
-50°C, 0.028
ASTM C177
Density Range 60-80Kg/m³ 40-60Kg/m³ ASTM D1622
Recommend Operation Temperature -200°C to 125°C -50°C to 105°C -
Percentage Of Close Areas >95% >95% ASTM D2856
Moisture Performance Factor NA <1.96x10g(m.m.Pa) ASTM E 96
Wet resistance Factor μ NA >10000 EN12086 / EN13469
Water Vapor Permeability Coefficient NA 0.0039g/h.m² (25mm thickness) ASTM E 96
PH ≥8.0 ≥8.0 ASTM C871
Tensile Strength Mpa -100°C, 0.30
-165°C, 0.25
0°C, 0.15
-50°C, 0.218
ASTM D1623
Compressive Strength Mpa -100°C, ≤0.3 -40°C, ≤0.16 ASTM D1621
Insulation Application Scene

With more than four decades of dedicated experience in manufacturing and applications.

Frequently Asked Questions (FAQ)

What are the impact resistance features of this adiabatic system?
The cryogenic elastomer material absorbs mechanical impact and vibration energy caused by external machinery, protecting the overall system structure from structural fatigue and damage.
What is the thermal conductivity of Kingflex ULT at cryogenic temperatures?
It features excellent low thermal conductivity under extreme conditions: 0.028 W/(m·K) at -100°C and 0.021 W/(m·K) at -165°C.
What is the recommended operating temperature range for Kingflex ULT and LT?
Kingflex ULT is optimized for temperatures ranging from -200°C to 125°C. Kingflex LT is recommended for temperatures from -50°C to 105°C.
Where is the ULT insulation system typically applied?
It is widely used in low-temperature storage tanks, industrial gas & agricultural chemical production plants, platform piping, gas stations, and nitrogen plants.
What are the density specifications for these insulation materials?
Kingflex ULT has a density range of 60-80 kg/m³, while Kingflex LT has a density range of 40-60 kg/m³.
What is the close-cell percentage of the material, and why is it important?
Both ULT and LT grades have a close-cell percentage exceeding 95%. This high closed-cell ratio ensures superior resistance to water vapor transmission and preserves stable insulation properties over time.